What is MSV?
MSV is Multi Selector Valve and Used in Oil and Gas industry. MSV is used to connect multiple Wells, to send oil to production and test separators.Read More…
It's our own way….
Answer
MSV is Multi Selector Valve and Used in Oil and Gas industry. MSV is used to connect multiple Wells, to send oil to production and test separators.Read More…
Foot valve is provided in suction of lift pumps or PCP (Progressive Cavity Pumps)(where fluid level is below pump location). This helps in initial priming up of the pump.Read More…
AFC means “Approved for Construction” and AFD means “Approved for Design”. AFC drawings are used for starting and doing Construction activities, whereas AFD drawings are used for starting actual design of detail engineering.Read More…
Cetane Number – experimental, CI – ASTM 4357 calculated from Sp Gravity, 10, 50, 90 % recovery temperature. Diesel index = (Aniline point in 0F * API)/100 Diesel Index = (Cetane Number – 10)/0.72 Aniline point is the lowest temperature at which the oil is completely miscible with an equal volume of aniline – high aniline point indicates presence of Paraffinic components and hence bettRead More…
Water has lowest volume at Minus 4 deg C, below this it again expands and exerts pressure on the glass walls, which leads in crack on bottle.Read More…
TSV or TRV (Thermal safety valve or Thermal Relief Valve) is used to take care of pressure build up due to thermal expansion. It is provided at places where a liquid can remain in blocked up state with no room for expansion due to temperature rise.Read More…
CPI means Corrugated Plate Interceptor – Which is used in water treatment.Read More…
Under ground lines have a protective coating of asphalt which will melt and spoil if subjected to high temperature.Read More…
Should an injured person remain away as a result of accident for more than a day (excluding the day of accident and the day of reporting), it is treated as lost time accident. Example – Joe meets with an accident on Monday and goes home. He does not sufferRead More…
As per BIS classification of hazardous area – zone zero is where explosive atmosphere is continuously present – like vapor space in tanks which are open to air and contain hydrocarbon or flammable material which for explosive mixture with air.Read More…